== Nelson River HVDC Transmission System, 1972 ==


Are you a member of this section? Please help expand the article by using the edit tab....  
[[Image:Nelson River HVDC System.jpg|thumb]][[IEEE Winnipeg Section History|IEEE Winnipeg Section]], Dedication: 3 June 2005 


[http://webmail.itl.rtu.lv/ieee/ Link to Section Homepage]
''On 17 June 1972, the Nelson River High Voltage Direct Current (HVDC) transmission system began delivery of electric power. It used the highest operating voltage to deliver the largest amount of power from a remote site to a city. The bipolar scheme gave superior line reliability and the innovative use of the controls added significantly to the overall system capabilities. Finally, the scheme used the largest mercury arc valves ever developed for such an application.''


<br>
'''The two plaques may be viewed at either&nbsp;Manitoba Hydro's Radisson and Henday Station&nbsp;(Nelson&nbsp;River),Manitoba, Canada, or at Manitoba Hydro's Dorsey Station, Rosser, Manitoba, about 26km northwest of Winnipeg, Canada.'''


== BACKGROUND  ==
The Province of Manitoba is situated in the center of Canada, immediately north of the Midwest United States. The Nelson River, located in the province, was up until the early 1960s an untapped resource for hydroelectric power. To provide electricity to the growing demand of the province, the government decided to tap into this abundant resource. Approximately 4,000 MW of generating capacity w as developed, 3,600 MW of which was hydro. Most of the hydro generation is located in the northern portion of the province. Quite remote from the load center in the south, Manitoba's two largest generating plants, Kettle Rapids and Long Spruce, with a combined capacity of 2200 MW, are located in the north.


The IEEE Latvia Section is part of Region 8 and covers the area of the Republic of Latvia.<br>&nbsp;&nbsp; &nbsp; The first talks about foundation of IEEE Latvia Section started in 2004, when IEEE Lithuania Section Officers visiting Riga Technical University. Finally, in 2007, during the meeting of European Nordic and Baltic countries IEEE Section officers, which was held in Riga, IEEE members from Latvia formed petition for the creation of Latvia Section.<br>&nbsp;&nbsp; &nbsp; IEEE Latvia Section was founded February 16, 2008, with the first elected Chair Professor Leonids Ribickis. Since its creation, the Latvia Section has been working professionally in various activities, mainly within the city of Riga.<br>
More than 550 miles of transmission lines from the Kettle Generating Station to Winnipeg were constructed. Power is generated in alternating current (ac) and converted to direct current (dc) for economical reasons. Direct current was chosen because it loses less power and is more stable. Also, dc lines are 2/3 less expensive than ac lines.  


== SECTION OFFICERS  ==
To support the dc transmission line, over 3,900 guyed towers and 96 self supporting towers had to be constructed. One of the challenges of establishing this transmission line was the varied terrain and the presence of permafrost, which existed in some areas at 30ºF to 32º F (-1ºC to 0ºC), making the foundation subject to a reduction in soil strength and settling of up to 3 feet (1 meter).


{| width="100%" border="1" cellpadding="1" cellspacing="1"
The output of these plants (Kettle and Long Spruce) is then transmitted from Radisson and Henday Converter Stations (ac to dc) , via the Nelson River dc line, more than 600 miles (965 km) southward to Dorsey Station, located near Winnipeg. Initial DC service was established in 1972 and expanded to match generation additions, bringing the present total transmission capability to 2 , 500 MW.
|-
| Year
| Chair
| Vice Chair
| Secretary
| Treasurer
|-
| 2008
| colspan="4" | Armands Srazds – Deputy Chair
|-
| 2009
| Leonids Ribickis<br>
| Elmars Bekeris
| Armands Srazds
| Atis Kapenieks
|-
| 2010
| Leonids Ribickis
| Andrejs Romanovs
| Oskars Krievs
| Atis Kapenieks
|-
| 2011
| Leonids Ribickis
| Andrejs Romanovs
| Oskars Krievs
| Atis Kapenieks&nbsp;
|}


<br>
The significance of this low-voltage line lies in the fact that for the first time two HVDC bipoles were paralleled and deparalleled using high voltage high-speed switches, the system being unique in the sense that Bipole 1 uses mercury arc valves while Bipole 2 comprises second generation thyristor valves.


== MEMBERSHIP  ==
A bipolar transmission line is defined as having two conductors consisting of one positive pole and one negative pole, which normally operate at equal current. The term bipole refers to the conversion equipment in the converter stations at both ends of Manitoba Hydro's HVDC transmission lines.


As of 1 January 2011, the IEEE Latvia Section has a total of 141 active members.
The other major advantage of the HVDC system is very low electric rates, one of the lowest in North America.  


[[Image:IEEE.LV-memb.JPG]]
== Map ==


== <br>CHAPTERS/AFFINITY GROUPS/STUDENT BRANCHES  ==
{{#display_map:54.218428, -97.613096~ ~ ~ ~ ~Winnipeg, Manitoba, Canada|height=250|zoom=10|static=yes|center=54.218428, -97.613096}}


*2009, IEEE Education Society Latvia Chapter was founded, with the first elected Chair Mr. Armands Strazds.
[[Category:Energy|{{PAGENAME}}]]
*2010, IEEE Computer Society Latvia Chapter was founded, with the first elected Chair Professor Janis Grundspenkis.
[[Category:Power_engineering|{{PAGENAME}}]]
*January 2011, the Latvia Section announced the foundation of a Joint Chapter of IEEE Power Electronic Society, IEEE Industrial Electronic Society and IEEE Industrial Application Society
[[Category:High-voltage_techniques|{{PAGENAME}}]]
*April 2011, IEEE Latvia Section Student Branch is planned to be founded.<br>
[[Category:Power_generation|{{PAGENAME}}]]
 
[[Category:Power_distribution|{{PAGENAME}}]]
== <br>THE BALTIC COOPERATION  ==
 
The IEEE Latvia Section participates in a group titled the Baltic Cooperation, which consists of the following IEEE Sections: [http://www.ieeeghn.org/wiki/index.php/IEEE_Denmark_Section_History Denmark], [http://www.ieeeghn.org/wiki/index.php/IEEE_Estonia_Section_History Estonia], [http://www.ieeeghn.org/wiki/index.php/IEEE_Finland_Section_History Finland], [http://www.ieeeghn.org/wiki/index.php/IEEE_Iceland_Section_History Iceland], [http://www.ieeeghn.org/wiki/index.php/IEEE_Latvia_Section_History Latvia], [http://www.ieeeghn.org/wiki/index.php/IEEE_Lithuania_Section_History Lithuania], [http://www.ieeeghn.org/wiki/index.php/IEEE_Norway_Section_History Norway], [http://www.ieeeghn.org/wiki/index.php/IEEE_Poland_Section_History Poland], [http://www.ieeeghn.org/wiki/index.php/IEEE_Russia_(Northwest)_Section_History Russia North-West], and [http://www.ieeeghn.org/wiki/index.php/IEEE_Sweden_Section_History Sweden]. The objective of the IEEE Baltic Cooperation is to create a functioning collaboration between the Baltic Region sections which shall result in common activities, such as; joint events, joint chapters and common utilization of IEEE resources.
 
== <br>MAJOR EVENTS<br>  ==
 
*October 2009, Celebration of 125th Anniversary of IEEE. Plenary report: “Scientific Research in Riga Technical University in 2009”, speaker Professor Leonids Ribickis, attendance: more than 200 IEEE members and guests from different countries.
*May 2010, IEEE Region 8 94th Committee Meeting in Riga, Latvia, May 7-9, 2010. Region 8 Committee awarded Latvia Section for Exemplary Service and Dedication as a host of the 94th IEEE Region 8 Committee Meeting.<br>
 
[[Media:IEEE_Geographic_Unit_Organizing_Document_-_Latvia.pdf|<br>IEEE Geographic Unit Organizing Document - Latvia]]<br>[[Media:IEEE.LV-memb.JPG|IEEE.LV-memb.JPG]]  
 
[[Category:IEEE]] [[Category:Geographical_units]] [[Category:Sections]]

Revision as of 19:06, 6 January 2015

Nelson River HVDC Transmission System, 1972

Nelson River HVDC System.jpg

IEEE Winnipeg Section, Dedication: 3 June 2005 

On 17 June 1972, the Nelson River High Voltage Direct Current (HVDC) transmission system began delivery of electric power. It used the highest operating voltage to deliver the largest amount of power from a remote site to a city. The bipolar scheme gave superior line reliability and the innovative use of the controls added significantly to the overall system capabilities. Finally, the scheme used the largest mercury arc valves ever developed for such an application.

The two plaques may be viewed at either Manitoba Hydro's Radisson and Henday Station (Nelson River),Manitoba, Canada, or at Manitoba Hydro's Dorsey Station, Rosser, Manitoba, about 26km northwest of Winnipeg, Canada.

The Province of Manitoba is situated in the center of Canada, immediately north of the Midwest United States. The Nelson River, located in the province, was up until the early 1960s an untapped resource for hydroelectric power. To provide electricity to the growing demand of the province, the government decided to tap into this abundant resource. Approximately 4,000 MW of generating capacity w as developed, 3,600 MW of which was hydro. Most of the hydro generation is located in the northern portion of the province. Quite remote from the load center in the south, Manitoba's two largest generating plants, Kettle Rapids and Long Spruce, with a combined capacity of 2200 MW, are located in the north.

More than 550 miles of transmission lines from the Kettle Generating Station to Winnipeg were constructed. Power is generated in alternating current (ac) and converted to direct current (dc) for economical reasons. Direct current was chosen because it loses less power and is more stable. Also, dc lines are 2/3 less expensive than ac lines.

To support the dc transmission line, over 3,900 guyed towers and 96 self supporting towers had to be constructed. One of the challenges of establishing this transmission line was the varied terrain and the presence of permafrost, which existed in some areas at 30ºF to 32º F (-1ºC to 0ºC), making the foundation subject to a reduction in soil strength and settling of up to 3 feet (1 meter).

The output of these plants (Kettle and Long Spruce) is then transmitted from Radisson and Henday Converter Stations (ac to dc) , via the Nelson River dc line, more than 600 miles (965 km) southward to Dorsey Station, located near Winnipeg. Initial DC service was established in 1972 and expanded to match generation additions, bringing the present total transmission capability to 2 , 500 MW.

The significance of this low-voltage line lies in the fact that for the first time two HVDC bipoles were paralleled and deparalleled using high voltage high-speed switches, the system being unique in the sense that Bipole 1 uses mercury arc valves while Bipole 2 comprises second generation thyristor valves.

A bipolar transmission line is defined as having two conductors consisting of one positive pole and one negative pole, which normally operate at equal current. The term bipole refers to the conversion equipment in the converter stations at both ends of Manitoba Hydro's HVDC transmission lines.

The other major advantage of the HVDC system is very low electric rates, one of the lowest in North America.

Map

Loading map...